品牌 | HOERBIGER賀爾碧格,其他 | 型號(hào) | HOERBIGER賀爾碧格 | 材質(zhì) | 球墨鑄鐵 |
形態(tài) | 蝶式 | 連接形式 | 法蘭 | 驅(qū)動(dòng)方式 | 電磁 |
流動(dòng)方向 | 單向 | 公稱通徑 | 20-160MM | 零部件及配件 | 閥體 |
外形 | 中型 | 標(biāo)準(zhǔn) | 國標(biāo) | 壓力環(huán)境 | 常壓 |
工作溫度 | 高溫 | 類型(通道位置) | 直通式 | 適用介質(zhì) | 空氣 |
規(guī)格 | 各種規(guī)格 |
HOERBIGER賀爾碧格螺桿空壓機(jī)進(jìn)氣閥型號(hào):HDKG40,HDKG50,HDKG65,HDKG85,HDKG120,HDKG160
歡迎各界同仁來人來電咨詢、洽談!詳細(xì)資料至公司索取。我們將以一流的產(chǎn)品,超低的價(jià)格,優(yōu)質(zhì)的服務(wù)與您密切合作,共謀發(fā)展!
企業(yè)官網(wǎng):www.senpull.cn 國內(nèi)熱線:400-6969-728 技術(shù)咨詢:021-51602627 51602681
【進(jìn)口壓縮機(jī)國際亞洲配送中心】【中國空壓機(jī)備品備件營銷中心】
螺桿空壓機(jī)進(jìn)氣閥工作原理
對(duì)于空壓機(jī)電磁閥的一個(gè)總的規(guī)律就是:電磁閥得電加載,失電卸載。有時(shí)候我們的設(shè)備有在卸載的情況下出現(xiàn)電流稍微有點(diǎn)大,22KW的卸載時(shí)電流有31A。初步懷疑進(jìn)氣閥沒關(guān)嚴(yán),因?yàn)樵跊]用氣的時(shí)候,機(jī)器卸載后,壓力還會(huì)慢慢上升,有時(shí)會(huì)高壓報(bào)警停機(jī)!而且在停機(jī)后,機(jī)器內(nèi)部還有一些殘余壓力無法卸放(在6公斤左右),導(dǎo)致再次啟動(dòng)時(shí),主機(jī)過載。
當(dāng)空壓機(jī)進(jìn)氣閥屬于常開式進(jìn)氣閥,壓縮機(jī)在沒有加載時(shí)電磁閥是打開的,壓縮機(jī)加載后電磁閥是關(guān)閉的.當(dāng)電磁閥打開時(shí),會(huì)有一路氣體去關(guān)閉進(jìn)氣閥,但是不能完全關(guān)死,還要保留進(jìn)氣空間,以維持壓縮機(jī)潤滑所需要的最小壓力,這個(gè)壓力一般在1.5bar;電磁閥關(guān)閉后,壓縮機(jī)會(huì)進(jìn)入正常工作狀態(tài),直至到設(shè)定的工作壓力,這取決于用戶.該進(jìn)氣閥有兩路管,一路放空;一路放掉閥中余氣,保證壓縮機(jī)正常加載。卸載時(shí),電流過大,說明罐壓較高,進(jìn)氣閥開度梢大,請(qǐng)調(diào)整放空螺釘,保證罐壓不會(huì)太高.
空壓機(jī)停機(jī)后,罐壓一般在60秒左右就可以完全排空,即壓力為0.而你的罐壓還有6bar,說明進(jìn)氣閥放空管路存在問題:1.可能是管路直徑過細(xì);2.組合閥孔口過小或是否雜物堵塞。
卸載后,壓力會(huì)有輕微的來回升高,但這個(gè)只是平衡需要,而且時(shí)間很短.不會(huì)上升到高壓停機(jī).高壓停機(jī)應(yīng)該是空壓機(jī)電磁閥存在問題,請(qǐng)檢查它是否完好,是否可以正常工作.不論什么樣的進(jìn)氣閥,都應(yīng)當(dāng)在卸載時(shí)維持罐壓在1.0~2.0BAR之間.過高對(duì)于空壓機(jī)的能量是很大的浪費(fèi)。
HOERBIGER賀爾碧格螺桿空壓機(jī)進(jìn)氣閥適應(yīng)各品牌空壓機(jī)進(jìn)氣閥
HOERBIGER He Erbi screw air compressor inlet valve type: HDKG40, HDKG50, HDKG65, HDKG85, HDKG120, HDKG160
Welcome colleagues from all walks of life come to inquire, negotiate! Detailed information to company to claim. We will be first-class products, low prices, high quality service in close cooperation with you and seek common development!
Corporate website: www.senpull.cn China hotline: 400-6969-728 technical consultation: 021-51602627 51602681
【 imported compressor international Asia distribution center 】 【 Chinese air compressor spare parts marketing center】
Screw air compressor working principle of the intake valve
For air compressor mechanical and magnetic valve is a general rule: the solenoid valve electricity load, loss of electric discharge. Sometimes we have the equipment under the condition of the discharge current slightly big, 22 kw current 31 a when unloading. Preliminary doubt inlet valve didn"t close tightly, because at the time of no gas, machine after unloading, the pressure will rise slowly, and sometimes high pressure alarm stop! And after the outage, the machine internal residual stress and some can"t discharge (around 6 kg), lead to start again, host overload.
Sky compressor inlet valve belongs to often open inlet valve, compressor without loading electromagnetic valve is opened, the compressor after loading the solenoid valve is closed. When the solenoid valve opens, there will be gas all the way to close the inlet valve, but can"t completely shut up, and keep intake space, in order to maintain the compressor lubrication required minimum pressure, the pressure is in commonly 1.5 bar; Solenoid valve is turned off, the normal work of the compressor enters the state, until to set the working pressure, depending on the user. The inlet valve tube have two road, empty all the way; Residual air in drain valve all the way to ensure that the normal load compressor. When unloading, current is too large, tank pressure is higher, the intake valve opening tip is big, please adjust the vent screw, ensure that tank pressure does not too high.
Air compressor after downtime, tank pressure generally within 60 seconds can be completely emptying, the pressure of 0. And you the tank pressure of 6 bar, shows that inlet valve vent piping problems: (1) may be pipe diameter carefully; 2. The combination valve orifice is too small or if sundry jam.
After unloading, the pressure may have a slight rise, back and forth with this just need balance, but time is short. Don"t rise to high downtime. High downtime should be air compressor mechanical and magnetic valve there is a problem, please check if it is in good condition, whether can work normal. No matter what kind of intake valve, shall be maintained when unloading tank pressure is between 1.0 ~ 2.0 BAR. Too much for the air compressor is a great waste of energy.
HOERBIGER He Erbi, screw air compressor inlet valve adapt each brand air compressor inlet valve