最近中文字幕在线mv视频7,伊人久久精品亚洲午夜,最近最好的中文字幕2019免费,中文字幕天天躁日日躁狠狠躁免费,一区二区三区在线 | 日本

家家通 | 所有行業(yè) | 所有企業(yè) 加入家家通,生意很輕松! ·免費(fèi)注冊(cè) ·登陸家家通 ·設(shè)為首頁(yè)
關(guān)于我們
關(guān)于我們
今日加盟
今日加盟
會(huì)員中心
會(huì)員中心
 
當(dāng)前位置: 首頁(yè) » 供應(yīng)產(chǎn)品 » 食品機(jī)械/飲料機(jī)械/食品飲料 » 豆制品機(jī)械 »Honeywell P/No:2106B1200 S/No:908

Honeywell P/No:2106B1200 S/No:908

<%=cpname%>
產(chǎn)品價(jià)格: 7/人民幣 
最后更新: 2016-01-12 08:28:46
產(chǎn)品產(chǎn)地: 5
發(fā)貨地: 8 (發(fā)貨期:當(dāng)天內(nèi)發(fā)貨)
供應(yīng)數(shù)量: 不限
有效期: 長(zhǎng)期有效
最少起訂: 1
瀏覽次數(shù): 84
詢價(jià)  試用會(huì)員產(chǎn)品
  • 公司基本資料信息
    • 北京康拉德科技有限公司
    • 張敏小姐 經(jīng)理
    • 會(huì)員[試用會(huì)員產(chǎn)品]
    • 郵件15321344403@163.com
    • 手機(jī)15321344403
    • 電話
    • 傳真
    • 地址北京市朝陽(yáng)區(qū)定福莊北里東領(lǐng)鑒筑3號(hào)樓5層7號(hào)
    • 進(jìn)入商鋪
     
    產(chǎn)品詳細(xì)說(shuō)明

    Honeywell P/No:2106B1200 S/No:908992304煤氣測(cè)漏報(bào)警儀探頭

    Max. stripping length 1,000 m
    for flat cable
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Supplied without cable.
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    110
    Flat cable system
    5 pole
    111
    Code 1
    Code 1
    1
    1
    Mechanical
    coding
    Conn. points
    per pole
    black
    Strain relief
    housing
    Connection
    style
    Descrtption Name
    Flat cable
    Output
    Power 3 pole
    Power: 5 x 2.5 mm 2 PVC
    Flat cable adapter with output,
    horizontal to line
    Flat cable adapter with output,
    horizontal to line.
    Optional tapping of the outer conductor
    L1, L2 oder L3
    Incoming supply
    Power 5 pole
    For wire diameters of
    5 – 13 mm
    Output
    Power 5 pole
    Flat cable adapter with output
    spring clamp technology 5 x 4 mm 2
    pre-assembled
    with female and connector
    Color Further connection
    with components
    of series
    Power: 5 x 2.5 mm 2 halogen-free
    Power: 5 x 10 mm 2 PVC
    Power: 5 x 10 mm 2 halogen-free
    light green
    light green with
    ”FR/LSOH“
    light green
    light green with
    ”FR/LSOH“
    GST 18i3
    at front through DIN rail terminal blocks
    5 x 10 mm 2
    GST 18i5
    Insulation
    piercing
    Screw
    V-screws
    yes
    yes
    Flat cable system
    5 pole
    With the option of the flat cable system,
    you can enjoy all the benefits of a
    modern electrical installation. Once the
    flat cable has been installed, you can
    quickly and reliably place branch circuits
    exactly where they are required, without
    re-terminating the cable. Modifications
    or extensions can be carried out both
    rapidly and economically. There are
    three versions of the flat cable adapter,
    all using the same insulation piercing
    technology. One incoming supply
    adapter for feeding the flat cable as well
    as outgoing adapter available in both
    5 and 3 pole variations
    With gesis  NRG the contact to the
    cable is made by turning in special
    insulation displacing V-screws. The flat
    cable system enables an installation to
    be subdivided into individual sections
    resulting in a flexible, clear and service-
    friendly installation system. In contrast
    to rigid busbar systems, the flat cable
    can be easily laid out in cable ducts.
    Application example General
    Coding
    Taps precisely where needed –
    without cutting the cable
    Please see the first pages of the Technical Data section for a table of the approximated relation between the conductor cross sections and the AWG sizes.
    112
    GST 18i3I B1 V F5 … 1 L1 92.031.5153.1
    GST 18i3I B1 V F5 … 2 L2 92.031.5253.1
    GST 18i3I B1 V F5 … 3 L3 92.031.5353.1
    GST 18i5 AFI F5 92.051.0553.1
    GST18i5 ASIF5 92.050.8153.0
    92.050.8653.0
    Flat cable adapter for power and
    routing GST 18i3/i5, 2.5 mm 2
    black
    Flat cable adapter power black
    light gray
    dark gray
    black
    Incoming supply
    for power
    Flat cable adapter power
    Flat cable adapter for GST 18i3
    Flat cable adapter for GST 18i5
    Name  Color  Part No.
    Name  Color  Part No.
    Name  Outer conductor tap  Part No.  Color
    Name  Part No.
    Screw technology for 5 pole with strain relief
    Connection style insulation piercing
    Incoming supply phases, N, ground
    Connection of round cable 5 x 2.5 mm 2
    Strain relief for cable ? 5 –13 mm
    Cover round cable outlet on one side
    Spring-loaded power for both sides, 5 pole
    Connection style insulation piercing
    Tap of phases, N, ground
    Direction of the connection cable select as required
    Small design (cable ducts) particulary for confined spaces
    Connection per pole 2, spring technology
    Strain relief for cable ? 5 –13 mm (H05VV, NYM) 1)
    fine stranded 0.5 – 1.5 mm 2 with ferrules 2)
    rigid 0.5 – 2.5 mm 2
    Cover Round cable outlet on both sides
    Further connection with components of GST 18i3, 3 pole
    Connection style insulation piercing
    Tap of phase, N, ground
    Output with  female connector GST18i3
    Output direction Horizontal cable layout
    Locking device required, on male connector
    Further connection with components of GST 18i5, 5 pole
    Connection style insulation piercing
    Tap of phases, N, ground
    Output with  female connector GST18i5
    Output direction Horizontal cable layout
    Locking device required, on male connector
    Flat cable system
    5 pole
    Supplied without cable
    See ”Technical Data“ for
    installation instructions.
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    113
    05.563.4700.0
    00.702.0303.7
    00.709.0303.7
    05.587.3156.1
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    Flat cable 5 pole 2.5 mm 2
    250/400V, 16 A, IP 20
    Cable cover
    Flat cable light green
    Flat cable, halogen-free light green
    Locking device black
    Cable cover
    Flat cable
    Flat cable
    Locking device
    Name  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Safety clearance guaranteed  between individual wires
    Installation on both sides of the cable
    Sheath strip length 20 mm
    PVC, for power 5 x 2.5 mm 2
    Insulating material PVC
    Color light green
    Max. stripping length 350 m
    halogen-free, for power 5 x 2,5 mm 2
    Insulating material thermoplastic PE compound
    Color light green, marked LSOH
    Max. stripping length 350 m
    – for snap-on
    (VDE 0628 requires the use of a locking device)
    Flat cable system
    5 pole
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    114
    GST18i5 ASI EF8 92.050.8253.0
    92.050.8853.0
    GST18i5 ASI AF8 92.050.8653.0
    Flat cable adapter for power 5 pole
    250/400 V, 50 A, IP 20
    Incoming supply for
    power
    Center point supply
    for power
    Flat cable adapter for
    power
    Name  Color  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Screw technology 5 pole with strain relief
    Incoming supply in flat cable at front
    DIN rail term. blocks for incom. supply 5 x 10 mm 2
    Connection of round cable metric cable gland M32
    Round cable NYM, H05VV-F, 5 x 10 mm 2
    Strain relief for Wieland flat cable
    Dimensions (L x W x H) 260 x 90 x 70 mm
    Screw technology 5 pole with strain relief
    Incoming supply in flat cable at front
    DIN rail term. blocks for incom. supply 5 x 10 mm 2
    Connection of round cable metric cable gland M32
    Round cable NYM, H05VV-F, 5 x 10 mm 2
    Strain relief for Wieland flat cable
    Dimensions (L x W x H) 260 x 90 x 70 mm
    Spring technology for power, 5 pole with strain relief
    Connection style insulation piercing
    Tap of phases, N, ground
    Strain relief for cables 2.5 – 4 mm 2 (H05VV, NYM)
    Output spring technology
    solid/fine-stranded conductor 5 x 4 mm 2
    Dimensions (L x W x H) 110 x 51 x 48 mm
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    Supplied without cable.
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    115
    05.563.9353.0
    00.702.0306.7
    00.709.0306.7
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    Flat cable 5 pole, 10 mm 2
    250/400 V, 50 A, IP 20
    Cable cover
    Flat cable PVC light green
    Flat cable halogen-free light green
    Cable cover
    Flat cable
    Flat cable
    Name  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Safety clearance guaranteed  between individual wires
    Installation on both sides of the cable
    Sheath strip length 20 mm
    PVC, containing halogen
    Insulating material PVC, containing halogen
    Color light green, RAL 6027
    Stripping length to be specified (max. 500 m)
    Dimensions (B x H) 38.5 x 10 mm
    halogen-free
    Insulating material thermoplastic PE compound
    Color light green, RAL 6027
    Marked FR/LSOH
    Stripping length to be specified (max. 500 m)
    Dimensions (B x H) 38.5 x 10 mm
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions..
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    116
    GST18i5 ASI F9 92.050.8453.0
    GST18i5 ASI AF9 92.050.8553.0
    G0.000.0044.7
    Flat cable adapter for power 5 pole, 16 mm 2
    250/400 V, 50 A, IP 65
    Incoming supply for
    power
    Name  Color  Part No.
    Name  Color  Part No.
    Screw technology 5 pole
    Connection style insulation piercing
    Tap of phases, N, ground
    Connection of round cable 5 x 16 mm 2 , screw connection
    Cable gland not included in delivery
    Metric cable gland see Accessories
    Dimensions (L x W x H) 200 x 85 x 91 mm
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    See ”Technical Data“ for installation instructions.
    Flat cable adapter
    Flat cable adapter
    incl. circuit
    breaker
    Name  Color  Part No.
    Screw technology 5 pole
    Connection style insulation piercing
    Tap of phases, N, ground
    Outputs 2, screw technology
    solid/fine-stranded conductor 5 x 6 mm 2 , 32 A
    Cable gland not included in delivery
    Metric cable gland see Accessories
    Dimensions (L x W x H) 200 x 85 x 73 mm
    Flat cable adapter for
    power (output)
    Flat cable adapter incl. circuit breaker
    Connection style insulation piercing
    Schutzgrad IP 20
    Tap of phases, N, ground
    Protected by 3 circuit breakers B 16 A 1)
    Output Connector, female, GST 18i
    1 x 5 pole (GST 18i5)
    3 x 3 pole (GST 18i3)
    L1 / L2 / L3, N, ground
    Outputs
    Dimensions (L x W x H) 220 x 110 x 110 mm
    Supplied without cable.
    See ”Technical Data“ for installation instructions.
    117
    05.563.9453.0
    00.702.0307.3
    00.709.0307.3
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    Flat cable 5 pole, 16 mm 2 ,
    250/400 V, 63 A, IP 65
    Cable cover
    Flat cable, PVC light gray
    Flat cable, halogen-free light gray
    Cable cover
    Flat cable
    Flat cable
    Name  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Safety clearance guaranteed  between individual wires
    Installation on both sides of the cable
    Sheath strip length 20 mm
    PVC, containing halogen
    Insulating material PVC, containing halogen
    Color light gray
    Stripping length to be specified
    Dimensions (B x H) 48.5 x 11.3 mm
    halogen-free, with marking FR/LSOH
    Insulating material thermoplastic PE compound
    Color light gray
    Marked FR/LSOH
    Stripping length to be specified
    Dimensions (B x H) 48.5 x 11.3 mm
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions..
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Supplied without cable
    118
    95.350.0200.0
    95.300.0300.0
    05.562.3000.0
    05.563.9753.0
    Flat cable system
    5 pole
    Flat cable accessories
    Sheath stripping tool 95.350.0200.0
    Cable cutter 95.300.0300.0
    Cable clip 05.562.3000.0
    Cable clip 05.563.9753.0
    Sheath
    stripping
    tool
    Cable cutter
    Cable clip for flat cable
    2.5 mm 2
    Cable clip for flat cables
    10.0 mm 2
    16.0 mm 2
    Name  Part No.
    Name  Part No.
    Name  Color  Part No.
    Name  Part No.
    for cutting the cable to length
    for stripping the sheath from flat cables
    for flat cable
    for flat cables
    119
    95.350.0500.0
    16 – 28 mm Z5.507.1953.0
    7 – 16 mm Z5.507.1553.0
    11 – 18 mm Z5.507.1521.0
    05.507.4153.0
    Flat cable system
    5 pole
    Flat cable accessories
    Sheath stripping knife 95.350.0500.0
    Sheath stripping knife
    Name  Part No.
    for stripping the sheath from the flat cable
    Cable gland M40 x 1.5 16 – 28 mm Z5.507.1953.0
    Cable gland M25 x 1.5 7 – 16 mm Z5.507.1553.0
    Cable gland, metal M25 x 1.5 11 – 18 mm Z5.507.1521.0
    Blanking plug M25 x 1.5 05.507.4153.0
    Cable gland
    for junction boxes
    Blanking plug
    for junction boxes
    Name  Gland  Wire range mm Part No.
    M40 x 1.5
    M25 x 1.5
    M25 x 1.5
    M25 x 1.5
    Name  Gland  Wire range mm Part No.
    120
    Flat cable system
    5 pole + 2 pole
    121
    Code 1
    Code 1
    1
    1
    Code 1
    Code 3
    GST 18i5
    GST 18i3
    BST 14i2
    BST 14i3
    Flat cable system
    5 pole + 2 pole
    Application example General
    Power supply and signal section
    combined in one cable
    By choosing a flat cable system you
    gain all benefits of modern electrical
    installation. Once the flat cable is drawn
    in, you can set branches fast and safely
    exactly in the position where they are
    required - without having to interrupt
    the line! Re-installation and extensions
    can therefore be managed in a fast and
    economic way.
    The 5+2 pole flat cable combines main
    power supply and signal section in
    one cable. This connection style has
    proven to be of great advantage in many
    applications, as only one cable has to
    be installed. Separate infeed boxes are
    available for the main power or signal
    section and supply the flat cable via
    a screw connector. The modular flat
    cable adapters serve as output and
    therefore function as transition to the
    chosen product line.
    Just as required, it might either be
    GST 18i3 (power 3 pole, L1, L2, L3),
    GST 18i5 (power 5 pole) or BST 14i2/3
    (KNX bus / control signals).
    Further connection leading to the consumer is done via connectors
    of the chosen line and coding. Mechanically coded means that only
    the matching male and female connectors can be plugged together,
    even in the correct pole configuration. Thus you can be sure that
    your different applications are clearly distinguished - without having
    to rework wrong connections.
    Mechanical
    coding
    Conn. points
    per pole
    black
    Strain relief
    housing
    Connection
    style
    Descrtption Name
    Flat cable
    Output
    Power 3-polig
    Power: 5 x 2.5 mm 2 Bus: 2 x 1.5 mm 2
    PVC screen
    Incoming supply
    Power 5 pole
    For wire diameters of
    5 – 13 mm
    Output
    Power 5 pole
    pre-assembled
    with female and connector
    Color Further connection
    with components
    of series
    purple
    Insulation
    piercing
    Screw
    V-screws
    yes
    yes
    Coding
    purple
    with “FR/LSOH“
    greem
    black
    Output KNX bus
    2 pole
    Output bus/
    Control signals
    2 pole
    Incoming supply
    bus/
    Control signals
    2 pole
    Power: 5 x 2.5 mm 2 Bus: 2 x 1.5 mm 2
    Halogen-free screen
    For wire diameters of
    3 – 8 mm
    (can be combined with
    output to BST)
    Versions L1, L2, L3
    (can be combined with
    output to BST)
    (can be combined with
    output to GST)
    (can be combined with
    output to GST
    Please see the first pages of the Technical Data section for a table of the approximated relation between the conductor cross sections and the AWG sizes.
    122
    GST18i5 ASI 92.050.8053.0
    BST14i2 ASI 93.420.1053.0
    Flat cable system
    5 pole + 2 pole
    GST18i5 ASI black
    BST14i2 ASI black
    Incoming supply
    for power
    5 pole
    Incoming supply for bus /
    control signal 2 pole
    Name  Color  Part No.
    Name  Color  Part No.
    Screw technology 5 pole with strain relief
    Connection style insulation piercing
    Incoming supply phases, N, U
    Connection of 5 x 2.5 mm2 round cables
    Strain relief of cable ? 5 –13 mm
    Cover Round cable output on one side
    Screw technology 2 pole with strain relief
    Connection style insulation piercing
    Incoming supply signals
    Connection of 2 x 1.5 mm2 round cables
    Strain relief of cable ? 3 – 8 mm
    Cover Round cable output on one side
    Supplied without cable.
    See ”Technical Data“ for
    installation instructions..
    Supplied without cable.
    See ”Technical Data“ for
    installation instructions..
    Incoming supply for power 5 pole and
    bus/control signal 2 pole, 16 A
    123
    GST 18i3I B1 V … 1 L1 92.031.4153.1
    GST 18i3I B1 V … 2 L2 92.031.4253.1
    GST 18i3I B1 V … 3 L3 92.031.4353.1
    GST 18i5 B1 V 92.051.0353.1
    Flat cable adapter for GST 18i5
    for power 5 pole
    Flat cable system
    5 pole + 2 pole
    Flat cable adapter for power and
    routing GST 18i3/i5, 16 A
    light gray
    dark gray
    black
    Flat cable adapter for GST 18i3
    for power 3 pole
    Name  Output outside conductor  Part No.
    Name  Part No.
    Routing with components of GST 18i3, 3 pole
    Connection style insulation piercing
    Incoming supply Phases, N, U
    Output with Connector, female, GST18i3
    Output direction Cable orientation in right angle
    Locking device required on male connector
    Routing with components of GST 18i5, 5 pole
    Connection style insulation piercing
    Incoming supply Phases, N, U
    Output with  Connector, female, GST18i5
    Output direction Cable orientation in right angle
    Locking device required on male connector
    Supplied without cable.
    See ”Technical Data“ for installation instructions..
    Supplied without cable.
    See ”Technical Data“ for installation instructions..
    124
    BST 14i2I B1 V ZB 93.421.0853.0
    BST 14i3I B1 V ZB 93.421.2853.0
    Flat cable adapter KNX bus and
    control signals BST 14i2/i3, 50 V, 3 A
    Flat cable system
    5 pole + 2 pole
    Flat cable adapter for BST 14i2
    for KNX bus 2 pole
    Name  Part No.
    Routing with components of BST 14i2, 2 pole
    Connection style insulation piercing
    Incoming supply KNX bus signal, 2 pole
    Output with  Connector, female, BST14i2
    Output direction Cable orientation in right angle
    Routing with components of BST 14i3, 2-polig
    Connection style insulation piercing
    Incoming supply no screen,
    3rd pole left empty
    Output with  Connector, female, BST14i3
    Output direction Cable orientation in right angle
    Supplied without cable.
    See ”Technical Data“ for installation instructions..
    Supplied without cable.
    See ”Technical Data“ for installation instructions..
    Flat cable adapter for BST 14i3
    for control signals
    Name  Output outside conductor  Part No.
    125
    05.562.2900.0
    00.702.0323.9
    00.709.0323.9
    05.587.3156.1
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    1+ = Bus
    2– = Bus
    U = GN/YE
    N = BU
    1 = BN
    2 = BK
    3 = GY
    1+ = Bus
    2– = Bus
    Flat cable 5 pole, 10 mm 2
    250/400 V, 50 A, IP 20
    Cable cover
    Flat cable
    Flat cable halogen-free
    Name  Part No.
    Name  Color  Part No.
    Name  Color  Part No.
    Safety clearance guaranteed  between individual wires
    Installation on both sides of the cable
    Sheath strip length 20 mm
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Functional reliability can only be
    guaranteed when the original cable is used.
    See ”Technical Data“ for installation instructions.
    Flat cable system
    5 pole + 2 pole
    Supplied without cable.
    Cable cover
    Flat cable PVC purple
    Flat cable halogen-free purple
    Locking device black
    Locking device
    Name  Color  Part No.
    – for snap-on
    (VDE 0628 requires the use of a locking device)
    PVC, for power 5 x 2.5 mm 2 and bus 2 x 1.5 mm 2
    Insulating material PVC, containing halogen
    Color purple
    Screen three-fold, satisfies KNX standard
    Max. cutting length 350 m
    PVC, for power 5 x 2.5 mm 2 and bus 2 x 1.5 mm
    Insulating material thermoplastic PE compound
    Color purple
    Screen three-fold, satisfies KNX standard
    Marking LSOH
    Max. cutting length 350 m
    126
    95.350.0200.0
    95.300.0300.0
    05.562.3000.0
    05.563.9753.0
    Flat cable accessories
    Sheath stripping tool
    Cable cutter
    Sheath
    stripping
    tool
    Cable cutter
    Name  Part No.
    Name  Part No.
    For cutting the cable to length
    For stripping the sheath from flat cables
    Flat cable system
    5 pole + 2 pole
    Cable clip
    Cable clip
    Cable clip for flat cable
    Cable clip for flat cable
    10 mm 2
    16 mm 2
    supplied without cable
    For flat cable
    Name  Part No.
    Name  Part No.
    127
    Flat cable system
    5 pole + 2 pole
    360
    1. 2. 3. 4.
    361
    Flat cable system
    1. When connecting flat cable
    adapters for mains and EIB
    bus/control signal, note the
    latching side (3 pole on the left,
    5 pole on the right). Latch the
    components together. Place the
    terminal block on the flat cable,
    observing the coding on the cable.
    2.Slide on the base plate – note the
    coding of the terminal block and
    cable (see diagram on the left).
    The grooves on the terminal block
    as well as on the base plate
    indicate the correct position of the
    adapter on the cable. If it is not
    positioned correctly, it is only
    possible to slide on the base plate
    using a great deal of force.The
    unit must then be rotated by 180°
    3.Turn the slotted screws in the flat
    cable until they reach the stop
    Mains: torque  = 0.7 Nm
    Bus: torque  =1.0 Nm
    4.Place the cover on top.
    Additional notes:
    ? When mounting the connectors, a
    locking device must be used.
    ? To remove the cover, insert the
    screwdriver in the slot and lift
    gently.
    ? The ends of the flat cable must
    be terminated with the cable
    end cap. This guarantees the
    necessary insulation between bus
    conductors and power cables.
    ? Once the adapter has been
    removed, the sections of cable
    that have been terminated with
    piercing screws must be sealed
    with insulating tape.
    ? Caution: Do not connect the
    screen to ground.
    ? The functional reliability can only
    be guaranteed if original cable is
    used.
    7 pole flat cable system 5 pole flat cable system
    Installation instructions
    362
    Technical data
    Components :
    Mains
    Connection technology: Insulation-piercing contacts with plug-in outgoing circuit in accordance with
    Wieland GST coding
    Terminal screws: Tightening torque: 0.8 Nm
    Rated voltage: 250 V/400 V
    Rated current: 16 A
    Number of poles: 3, 5 pole
    Regulations: DIN VDE 0628,
    VDE 0606 T200 in preparation
    IEC 998-2-3, DIN EN 60998-2-3/VDE 0613-2-3
    Approvals: VDE, SEV
    Type of protection: IP 20, DIN VDE 0470 section 1/11.92
    Connection cable
    for incoming supply: ? 5 – 13 mm
    Materials: Insulation components: thermoplastic material, halogen-free
    Cover: polycarbonate, transparent
    Contact parts: brass, surface-plated
    tin-bronze, surface-plated
    Continuous temperature: 70 °C, Insulation components 100 °C
    Flammability load: Flat cable adapter GST 18i5 0.27 kWh
    Flat cable adapter GST 18i3 0.18 kWh
    Coding: Mechanical coding
    GST 18i, Code 1, black
    General: The voltage supply (incoming supply) in the flat cable is carried out using a
    screw-type flat cable adapter. The outgoing boxes can be adapted using
    insulation-piercing connection technology. The outgoing units themselves
    can be connected using gesis connector systems. The connectors must be
    locked with a locking device. The appropriate GST accessories should be
    used..
    Please note the installation instructions on page 366!
    Note: The functional reliability can only be guaranteed if original cable is used.
    363
    * ) * )
    Flat cable system 5 pole
    Technical data
    Flat cable
    PVC
    Quantity x
    conductor cross section: 5 x 2.5 mm 2
    Outer sheath:  PVC according to CENELEC
    HD 21.1 S2, TM2
    Color of sheath: Light green RAL 6027
    Weight: 270 g/m
    Dimension (W x H): 24 x 6 mm
    Flammability load: 0.778 kWh/m
    Flammability behavior: self-extinguishing according to
    IEC 60332.1
    Bending radius: min. 60 mm
    Structure:
    Copper conductor: bare, fine-stranded according to
    CENELEC HD 383 S2, Class 6
    Wire insulation: PVC according to
    CENELEC HD 21.1 S2, TI2
    Color of wires:
    Technical data:
    Conductor cross section: 2.5 mm 2
    Test voltage: 4 kV
    Rated voltage: 450/750 V
    Test current: according to IEC 60364-5-523
    DC resistance: 7.98 ?/km
    Halogen-free
    5 x 2.5 mm 2
    Thermoplastic PE compound, halogen free and no
    corrosive gases according to DIN VDE 0472
    Section 813
    Light green RAL 6027
    260 g/m
    24 x 6 mm
    0.671 kWh/m
    self-extinguishing according to IEC 60332.1
    Low level of smoke development IEC 61034-1/2
    min. 60 mm
    bare , fine-stranded according to
    CENELEC HD 383 S2, Class 6
    Cross-linked, halogen free and
    flame resistant Ground
    2.5 mm 2
    4 kV
    450/750 V
    according to IEC 60364-5-523
    7.98 ?/km
    * ) The cable colors have been adapted to the new European
    standard HD 208 S2. The assignment corresponds to
    international recommendations.
    364
    Technical data
    Bus
    Connection technology: Insulation-piercing contacts with plug-in outgoing circuit in accordance
    with Wieland GST, BST, EST coding
    Terminal screws: Tightening torque: 1.0 Nm
    Rated voltage: 50 V
    Rated current: 3 A
    Number of poles: 2 pole (+,-)
    Regulations: EIB manual
    Approvals: according to EIB manual
    Connection cable
    for Incoming supply: ? 3 – 8 mm
    Materials: Insulation components: thermoplastic material, halogen free
    Cover: polycarbonate, transparent
    Contact parts: brass, surface-plated
    tin-bronze, surface-plated
    Continuous temperature: 70 °C, Insulation components 100 °C
    Flammability load: Flat cable adapter BST 14i 0.12 kWh
    Coding: Mechanical coding
    BST 14i
    Other coding: black
    General: Connectors must be used only in combination with a SELV or PELV
    power supply unit.
    The voltage supply (incoming supply) in the flat cable is carried out using a
    screw-type flat cable adapter. The outgoing boxes can be adapted using
    insulation-piercing connection technology. The outgoing units themselves
    can be connected using gesis connector systems.
    Please note the installation instructions on page 336!
    Note: The functional reliability can only be guaranteed if original cable is used.
    365
    Flat cable system 2 pole
    Technical data
    Flat cable
    PVC
    Quantity x
    Conductor cross section: 2 x 1.5 mm 2
    Outer sheath:  PVC
    Color of sheath: Dark grey
    Weight: 90 g/m
    Dimension (W x H): 11 x 6 mm
    Flammability load: 0.48 kWh/m
    Flammability behavior: Self-extinguishing according to
    IEC 60332.1
    Bending radius: min. 60 mm
    Structure:
    Copper conductor: Tin-plated according to CENELEC
    HD 383 S2, Class 5
    Wire insulation: PE according to DIN VDE 0207
    Section 2, 2YI2
    Wire colors: natural
    Shield: Twin screen from aluminium tape,
    electrically isolated
    Technical data:
    Conductor cross section: 1.5 mm 2
    Rated voltage: 300/300 V
    Rated current: 3 A
    DC resistance: 13.7 ?/km
    Capacitance: 70 pF/m
    Attenuation at 1 MHz: nom. 1.2 dB/100 m
    Surge impedance1 MHz: nom. 75 ?
    Halogen-free
    2 x 1.5 mm 2
    Thermoplastic PE Compound, halogen-free
    Dark grey
    86 g/m
    11 x 6 mm
    0.44 kWh/m
    Self-extinguishing according to IEC 60332.1
    Low level of smoke development IEC 61034-1/2
    min. 60 mm
    Tin-plated according to CENELEC
    HD 383 S2, Class 5
    PE according to DIN VDE 0207
    Section 2, 2YI2
    natural
    Twin screen from aluminium tape,
    electrically isolated
    1.5 mm 2
    300/300 V
    3 A
    13.7 ?/km
    70 pF/m
    nom. 1.2 dB/100 m
    nom. 75 ?
    366
    Technical data
    Components :
    Mains Bus
    Connection technology: Insulation-piercing contact with plug-in outgoing circuit in accordance with
    Wieland GST, BST, EST coding
    Terminal screws: Tightening torque: 0.8 Nm Tightening torque: 1.0 Nm
    Rated voltage: 250 V/400 V 50 V
    Rated current: 16 A 3 A
    Number of poles: 3/ 5 pole 2 pole (+,-)
    Regulations: VDE 0628, EIB manual
    Preliminary draft IEC 61535
    IEC 998-2-3 (insulation-piercing clamping device)
    Approvals: VDE, SEV according to EIB manual
    Type of protection: IP 20, DIN VDE 0470 section 1/11.92
    Connection cable
    for incoming supply: ? 5 – 13 mm ? 3 – 8 mm
    Materials: Insulation components: thermoplastic material, halogen-free
    Cover: polycarbonate, transparent
    Contact parts: brass, surface-plated
    tin-bronze, surface-plated
    Continuous temperature: 70 °C, Insulation components 100 °C
    Flammability load: Flat cable adapter GST 18i5 0,27 kWh
    Flat cable adapter GST 18i3 0,18 kWh
    Flat cable adapter BST 14i 0,12 kWh
    Coding: Mechanical coding
    GST 18i BST 14i
    Combination connector for mains and signal, type EST ....
    3 pole tap-off, all phases with standard GST 18i coding
    GST 18i3/5 color: black EIB coding: green
    Other coding: black
    General: The bus signal must have a SELV or PELV power supply unit.
    The voltage supply (incoming supply) in the flat cable is carried out using a
    screw-type flat cable adapter. The outgoing boxes can be adapted using
    insulation-piercing connection technology. The outgoing units themselves
    can be connected using gesis connector systems. The connectors must be
    locked with the adapter. The appropriate GST accessories should be used.
    Please note the installation instructions.
    Note: The functional reliability can only be guaranteed if original cable is used.
    * ) The cable colors have been adapted to the new European
    standard HD 208 S2.
    The assignment corresponds to international recommen-
    dations.
    367
    Flat cable system 7 pole
    Technical data
    Flat cable
    PVC
    Quantity x
    Conductor cross section: 5 x 2.5 mm 2 + 2 x 1.5 mm 2
    Outer sheath:  PVC according to CENELEC
    HD 21.1 S2, TM2
    Color of sheath: Purple RAL 4005
    Weight: 350 g/m
    Dimension (W x H): 32 x 6 mm
    Flammability load:  1.18 kWh/m
    Flammability behavior: Self-extinguishing according to
    IEC 60332.1
    Bending radius: min. 60 mm
    Power component
    Structure:
    Copper conductor:  bare, fine-stranded
    according to CENELEC HD 383 S2
    Class 6
    Wire insulation: PVC according to CENELEC
    HD 21.1 S2, TI2
    Wire colors: black, brown, black, blue,
    yellow/green
    Technical data:
    Conductor cross section: 2.5 mm 2
    Test voltage: 4 kV
    Rated voltage: 450/750 V
    Test current: according to IEC 60364-5-523
    DC resistance: 7.98 ?/km
    Bus component
    Structure:
    Copper conductor: tin plated according to CENELEC
    HD 383 S2, Class 5
    Wire insulation: PE according to DIN VDE 0207
    Section 2, 2YI2
    Wire colors: natural
    Shield: Twin screen from aluminium tape,
    electrically isolated
    Technical data:
    Conductor cross section: 1.5 mm 2
    Rated voltage: 300/330 V
    Rated current: 3 A
    DC resistance: 13.7 ?/km
    Capacitance: 70 pF/m
    Attenuation at 1 MHz: nom. 1.2 dB/100 m
    Surge impedance 1 MHz: nom. 75 ?
    Halogen-free
    5 x 2.5 mm 2 + 2 x 1.5 mm 2
    Thermoplastic PE Compound,
    halogen-free and no corrosive gases
    according to DIN VDE 0472 section 813
    Purple RAL 4005
    340 g/m
    32 x 6 mm
    0.99 kWh/m
    Self-extinguishing according to IEC 60332.1
    Low risk of fire spreading according to IEC 60332-3C
    Low level of smoke development IEC 61034-1/2
    min. 60 mm
    bare, fine-stranded
    according to CENELEC HD 383 S2
    Class 6
    Cross-linked, halogen free and flame resistant
    black, brown, black, blue,
    yellow/green
    2.5 mm 2
    4 kV
    450/750 V
    according to IEC 60364-5-523
    7.98 ?/km
    tin plated according to CENELEC
    HD 383 S2, Class 5
    PE according to DIN VDE 0207
    Section 2, 2YI2
    natural
    Twin screen from aluminium tape,
    electrically isolated
    1.5 mm 2
    300/300 V
    3 A
    13.7 ?/km
    70 pF/m
    nom. 1.2 dB/100 m
    nom. 75 ?
    368
    1. 2. 3.
    4. 5. 6.
    7 . 8. 9.
    70 mm
    1,5 - 4 mm 2
    Oder
    ou
    or
    12 mm
    Phillips Nr.2
    1,2...1,4 Nm
    10,6...12,4 lb-in
    Alle Schrauben bis zum Anschlag
    All screws until stopper
    Kr?ftig nach unten drücken
    Press strongly
    a b
    1,5 - 4 mm 2
    Installation instructions
    369
    gesis
    ?
    NRG
    * )
    Technical data
    Flat cable 5 x 10 mm 2
    PVC
    Quantity x
    conductor cross section: 5 x 10 mm 2
    Outer sheath:  PVC accord. to CENELEC HD 21.1 S2,
    TM2
    Color of sheath: light green, similar to RAL 6027
    Weight: 845 g/m
    Dimension (B x H): 38.5 x 10 mm
    Flammability load:  2.12 kWh/m
    Flammability behavior: self-extinguishing accord. to
    IEC 60332-1
    Structure:
    Copper conductor:  unplated, fine-stranded
    accord. to DIN VDE 0295 Class 5
    Wire insulation: PVC accord. to CENELEC HD 21.1 S2,
    TI2
    Wire colors:
    Technical data:
    Test voltage: 4 kV
    Nominal voltage: 690 V
    Test current: accord. to IEC 60364-5-523 and
    SEV NIN 42512.2
    DC resistance: 1.91 ?/km
    Bending radius: min. 100 mm
    * ) The cable colors have been adapted to the new
    European standard HD 208 S2. The assignment
    corresponds to international recommendations.
    L1
    PE
    L3
    N
    L
    L2=110 mm
    N =110 mm
    L3=110 mm
    PE=130 mm
    L1=130 mm
    2 2
    16 mm
    L
    L
    L2=220 mm
    N =220 mm
    L3=150 mm
    PE=150 mm
    L1=150 mm
    16 mm
    L
    0 mm
    370
    1. 2. 3.
    4. 5. 6.
    7 . 8. 9.
    Installation instructions
    O-ring
    or
    Clean
    cable surface
    Philips no. 2
    2 Nm
    18 lb-in
    Philips no. 2
    2.5 Nm
    18 lb-in
    Philips no. 2
    2.5 Nm
    18 lb-in
    Philips no. 2
    2.5 Nm
    18 lb-in
    All screws
    tightened down to
    the red marking.
    Additional information and notes:
    ? Flat cable 5 x 16 mm 2 , 450/750 V
    ? Box 2x (5 x 6 mm 2 )
    ? Use only with original cable
    371
    gesis
    ?
    NRG
    * ) * )
    Technical data
    Flat cable 5 x 16 mm 2
    PVC
    Outer sheath:  PVC oil-proof
    Color of sheath: light gray
    Weight: 1.3 kg/m
    Dimension (B x H):
    Flammability load:  2.95 kWh/m
    Flammability behavior: self-extinguishing accord. to
    IEC 60332-1
    Quantity x
    conductor cross section: 5 x 16 mm 2
    Structure:
    Copper conductor:  unplated, fine-stranded
    accord. to CENELEC HD 383 S2
    Class 6
    Wire insulation: PVC accord. to CENELEC HD 21.1 S3, TI3
    Wire colors:
    Technical data:
    Test voltage:
    Nominal voltage: 450/750 V
    Current-carrying capability:: accord. to IEC 60364-5-523 and
    SEV NIN 42512.2
    DC resistance: 1.15 ? /1000 m (20 °C)
    Bending radius: min. 113 mm
    Halogen-free
    Polyolefine, halogen-free
    light gray
    1.3 kg/m
    2.5 kWh/m
    No corrosive gas accord. to IEC 60754-2, low fire
    transmission accord. to IEC 60332-3, low smoke
    development accord. toIEC 61034
    5 x 16 mm 2
    unplated, fine-stranded accord. to
    CENELEC HD 383 S2 Class 6
    Thermoplastic PE Compo, halogen-free,
    flame-retardant
    450 /750 V
    accord. to IEC 60364-5-523 and
    SEV NIN 42512.2
    1.15 ? /1000 m (20 °C)
    min. 113 mm
    * ) The cable colors have been adapted to the new
    European standard HD 208 S2. The assignment
    corresponds to international recommendations.
    MFG. #5400979 - REV S
    5/09
    PRINTED IN USA PAGE 1 OF 4
    OSYSU-1,-2
    OUTSIDE SCREW AND YOKE
    VALVE SUPERVISORY SWITCH
    UL, ULC and CSFM Listed, FM Approved, NYMEA Accepted,
    CE Marked
    Dimensions: 6.19"L X 2.25"W X 5.88"H
    15,7cm L X 5,7cm W X 14,6cm H
    Weight:  2 lbs (0,9 kg)
    Enclosure: Cover - Die-Cast
    Finish - Red Spatter Enamel
    Base - Die Cast Zinc
    All parts have corrosion resistant fi nishes
    Cover Tamper: Tamper Resistant Screws
    Optional Cover Tamper Switch Available
    Contact Ratings:
    OSYSU-1: One set of SPDT (Form C)
    OSYSU-2: Two sets of SPDT (Form C)
    15 Amps at 125/250VAC
    2.5 Amps at 30VDC resistive
    Environmental Limitations:
    -40°F to 140°F (-40°C to 60°C)
    NEMA 4 and NEMA 6P Enclosure (IP67)
    Indoor or outdoor use (Not for use in hazardous locations. See
    Bulletin No. 5400705 OSYS-U-EX for hazardous locations).
    Conduit Entrances:
    2 knockouts for 1/2" conduit provided
    Service Use:
    Automatic Sprinkler  NFPA-13
    One or two family dwelling  NFPA-13D
    Residential occupancy up to four stories NFPA-13R
    National Fire Alarm Code NFPA-72
    Potter Electric Signal Company, LLC ? St. Louis, MO ? Phone: 866-956-0988/Canada: 888-882-1833 ? www.pottersignal.com
    General Information
    The OSYSU is used to monitor the open position of an OS&Y
    (outside screw and yoke) type gate valve. This device is
    available in two models; the OSYSU-1, containing one set
    of SPDT (Form C) contacts and the OSYSU-2, containing
    two sets of SPDT (Form C) contacts. These switches mount
    conveniently to most OS&Y valves ranging in size from 2" to
    12" (50mm to 300mm). They will mount on some valves as
    small as ?" (12,5mm).
    The cover is held in place by two tamper resistant screws that
    require a special tool to remove. The tool is furnished with each
    device and should be left with the building owner or responsible
    party. Replacement or additional cover screws and hex keys are
    available. See Ordering Information.
    Optional Cover Tamper Switch
    A fi eld installable cover tamper switch is available as an option
    which may be used to indicate removal of the cover. See
    Ordering Information.
    Testing
    The OSYSU and its associated protective monitoring system
    should be inspected and tested in accordance with applicable
    NFPA codes and standards and/or the authority having
    jurisdiction (manufacturer recommends quarterly or more
    frequently).
    Ordering Information
    Model Descrtption Stock No.
    OSYSU-1 Outside Screw & Yoke
    Supervisory Switch
    (Single switch)
    1010106
    OSYSU-2 Outside Screw & Yoke
    Supervisory Switch
    (Double switch)
    1010206
    Cover Screw 5490424
    Hex Key for Cover Screws and
    Installation Adjustments
    5250062
    Optional Cover Tamper Switch Kit 0090131
    MFG. #5400979 - REV S
    5/09
    PRINTED IN USA PAGE 2 OF 4
    OSYSU-1,-2
    OUTSIDE SCREW AND YOKE
    VALVE SUPERVISORY SWITCH
    FIG. 1  SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" SIZES
    and smooth the edges of the groove to prevent damage to the valve
    packing and to allow the trip rod to move easily in and out of the
    groove as the valve is operated.
    7. Mount the OSYSU with the trip rod centered in groove.
    8. Final adjustment is made by loosening 2 screws (see Fig. 1) and
    sliding the OSYSU on the bracket. Adjustment is correct when
    switches are not activated with the trip rod seated in the valve stem
    groove and that the switches activate when the trip rod moves out
    of the groove.
    9. Tighten the adjustment screws and all mounting hardware. Check
    to insure that the rod moves out of the groove easily and that the
    switches activate within one turn when the valve is operated from
    the FULL OPEN towards the CLOSED position.
    NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE
    STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH
    BEING ACTIVATED BY THE STEM THREADS COULD RESULT
    IN A FALSE VALVE OPEN INDICATION.
    SMALL VALVE INSTALLATION
    1. Remove and discard "C" washer and roller from the trip rod.
    2. With the valve in the FULL OPEN position, locate the OSYSU
    across the valve yoke as far as possible from the valve gland, so
    that the trip rod lays against the non-threaded portion of the valve
    stem.
    3. Loosen the locking screw that holds the trip rod in place and adjust
    the rod length (see Fig. 4). When adjusted properly, the rod should
    extend past the valve screw, but not so far that it contacts the clamp
    bar. Tighten the locking screw to hold the trip rod in place.
    NOTE: If trip rod length is excessive, loosen the locking screw
    and remove the trip rod from the trip lever. Using pliers, break off
    the one (1) inch long notched section (see Fig. 5). Reinstall trip rod
    and repeat Step 3 procedure.
    4. Mount the OSYSU loosely with the carriage bolts and clamp bar
    supplied. On valves with limited clearance use J-hooks supplied
    instead of the carriage bolts and clamp bar to mount the OSYSU.
    5. Mark the valve stem at the center of the trip rod.
    6. Remove the OSYSU. File a 1/8" deep groove centered on the mark
    on the valve stem utilizing a 3/16" diameter straight fi le. Round
    CLAMP
    BAR
    CARRIAGE
    BOLT
    DWG# 979-3
    BRACKET
    SLOTTED
    MOUNTING
    HOLES MAY BE
    USED FOR FINE
    ADJUSTMENT OF
    SWITCH ON
    BRACKET
    These switches mount conveniently to most 2" to 12" OS&Y valves. They will mount on some valves as small as 1/2". J-hooks
    may be required on valves with limited clearance.
    MFG. #5400979 - REV S
    5/09
    PRINTED IN USA PAGE 3 OF 4
    OSYSU-1,-2
    OUTSIDE SCREW AND YOKE
    VALVE SUPERVISORY SWITCH
    FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" SIZES
    LARGE VALVE INSTALLATION
    1. With the valve in the FULL OPEN position, locate the OSYSU across
    the valve yoke as far as possible from the valve gland, so that the trip
    rod lays against the non-threaded portion of the valve stem.
    2. Mount the OSYSU loosely with the carriage bolts and clamp bar
    supplied.
    3. Loosen the locking screw that holds the trip rod in place and adjust
    the rod length (see Fig. 4). When adjusted properly, the rod should
    extend past the valve screw, but not so far that it contacts the clamp
    bar. Tighten the locking screw to hold the trip rod in place.
    NOTE: If trip rod length is excessive, loosen the locking screw
    and remove the trip rod from the trip lever. Using pliers, break off
    the one (1) inch long notched section (see Fig. 5). Reinstall trip rod
    and repeat Step 3 procedure.
    4. Mark the valve stem at the center of the trip rod.
    5. Remove the OSYSU. File a 1/8" deep groove centered on the mark
    of the valve stem utilizing a 3/8" diameter straight fi le. Round and
    smooth the edges of the groove to prevent damage to the valve
    packing and to allow the trip rod to move easily in and out of the
    groove as the valve is operated.
    6. Mount the OSYSU loosely with the trip rod centered in groove.
    7. Final adjustment is made by loosening 2 screws (see Fig. 2) and
    sliding the OSYSU on the bracket. Adjustment is correct when
    switches are not activated with the trip rod seated in the valve stem
    groove and that the switches activate within one turn when the valve
    is operated from the FULL OPEN towards the CLOSED position.
    8. Tighten the adjustment screws and mounting hardware. Check to
    insure that the rod moves out of the groove easily and that the switches
    activate within one turn when the valve is operated from the FULL
    OPEN towards the CLOSED position.
    NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE
    STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH
    BEING ACTIVATED BY THE STEM THREADS COULD RESULT
    IN A FALSE VALVE OPEN INDICATION.
    3” THRU 12” (76mm THRU 300mm) VALVES
    USE CARRIAGE BOLTS. BOLTS MOUNT
    ON INSIDE OF YOKE, IF THERE IS
    SUFFICIENT CLEARANCE.
    SLOTTED
    MOUNTING HOLES.
    MAY BE USED FOR
    FINE ADJUSTMENT
    OF SWITCH ON
    BRACKET.
    DWG# 979-4
    BRACKET
    CLAMP BAR
    CARRIAGE BOLTS
    (2 REQUIRED)
    ROLLER
    GROOVE
    YOKE
    VALVE STEM
    TRIP ROD
    GLAND
    MFG. #5400979 - REV S
    5/09
    PRINTED IN USA PAGE 4 OF 4
    OSYSU-1,-2
    OUTSIDE SCREW AND YOKE
    VALVE SUPERVISORY SWITCH
    TYPICAL SWITCH ACTION
    Contacts shown in normal (valve open) condition.
    FIG. 3 DIMENSIONS FIG. 4  PARTS
    OUTGOING
    INCOMING
    DWG# 923-3
    4.75
    (12,1CM)
    6.19
    (15,7CM)
    4.75
    (12,1CM)
    3.62
    (9,2CM)
    3.00
    (7,6CM)
    5.88
    (15CM)
    3.88
    (9,9CM)
    ROD EXTENDED DWG# 979-5
    ROD RETRACTED AND
    BREAKAWAY SECTION
    REMOVED
    .88
    (2,2CM)
    2.25
    (5,7CM)
    2.00
    (5,1CM)
    1.56
    (4,0CM)
    BREAKING EXCESSIVE ROD
    LENGTH
    SWITCH TERMINAL
    CONNECTIONS
    CLAMPING PLATE
    TERMINAL
    TYPICAL ELECTRICAL CONNECTIONS
    CAUTION:
    An uninsulated section of a single conductor should
    not be looped around the terminal and serve as two
    separate connections. The wire must be severed,
    thereby providing supervision of the connection
    in the event that the wire becomes dislodged from
    under the terminal.
    LOCAL CIRCUIT
    TO POWER FOR
    INDICATING DEVICE
    TO SUPERVISORY CIRCUIT
    OF CONTROL PANEL
    COM.
    COM.
    N.O.
    N.C.
    INDICATING
    DEVICE
    N.O.
    N.C.
    END OF
    LINE
    RESISTOR
    DWG# 979-1
    OPEN VALVE
    POSTITON
    COM.
    SW #1
    COM.
    SW #2
    DWG# 979-2
    CLOSED VALVE
    POSTITON
    N.O.
    N.C.
    N.O.
    N.C.
    COM.
    SW #1
    COM.
    SW #2
    N.O.
    N.C.
    N.O.
    N.C.
    DWG# 979-7
    (WHITE) COM
    (RED) N.O.
    (BLACK) N.C.
    KNOCKOUTS FOR
    ELECTRICAL
    CONNECTIONS
    GROUND SCREW
    TRIP ROD
    LOCKING SCREW
    TRIP ROD
    DWG# 979-6
    COVER TAMPER
    SWITCH (OPTIONAL)
    ECOL Motors
    WE MOVE WHEN
    OTHERS STOP
    COMPANY BRIEF INTRODUCTION
    Shanghai Top Motor Co., Ltd., one of leading motor manufacturers in China with a famous brand,
    TECHTOP, specializes in production and sale of electrical produces, which are electric motors conformed
    to IEC, NEMA, GOST standard, permanent magnet motor, water pumps, generators, generating sets and
    the likes. The company has obtained ISO9001 Certificate and its products have Certificates of CSA, UL,
    CE, CCC etc..
    TECHTOP warmly welcomes cooperation with the customers all over the world and provides the
    best-quality products and most sincere service to the friends.
    WORKSHOP & TECHNOLOGY
    TECHTOP adopts computerized machine tools for metal parts; four cylinder oil hydraulic presses
    for stator stacking; vacuum high-pressure vanishing units for stator vanishing; clean-dry and
    auto-phosphorescing machines for motor housing, end shield, fan cover and other parts;
    electrostatic spraying-water screen-suspending line complexes for product surface painting.
    www.motor-techtop.com
    6
    ECOL MOTORS
    1
    M otor Spare Part List "Exploded Drawing"
    M ountings and Positions
    1. Screw
    2. Gasket
    3. Oil seal
    4. Front endshield
    5. B14 fl ange
    6. B5 fl ange
    7. TB cover
    8. TB fi xing screws
    9. TB upper gasket
    10. Terminal board fi xing nut
    11. Terminal bridge
    12. Terminal pin
    13. Terminal shim
    14. Terminal board
    15. TB fi xing screws
    16. TB base
    17. Cable gland
    18. TB bottomgasket
    19. Frame
    20. Preload washer
    21. Key
    22. Rotor
    23. Bearing
    24. NDE endshield
    25. Cooling fan
    26. Fan circlip
    27. Fan cover
    28. Fan cover fi xing shim
    29. Fan cover fi xing screws
    30. Endshield fi xing nut
    31. Rivet
    32. Nameplate
    33. Foot fi xing nut
    34. Foot fi xing screws
    35. Foot
    Mountings and positions for standard motors, according to IEC 60034-7,
    are defi ned by the codes mentioned in the following table.
    CONNECTION DIAGRAM
    V1 IM V1 IM 3011 Standard
    V3 IM V3 IM 3031 Upon request
    V5 IM V5 IM 1011 Upon request
    V1/V5 IM V15 IM 2011 Upon request
    Standards
    CEI 2-14 IEC 60034-7
    Frame Sizes
    56-200
    B3 IM B3 IM 1001 Standard
    B3/B5 IM B35 IM 2001 Standard
    B5 IM B5 IM 3001 Standard
    B14 IM B14 IM 4001 Standard
    B8 IM B8 IM 1071 Upon request
    B6 IM B6 IM 1051 Upon request
    B7 IM B7 IM 1061 Upon request
    Standards
    CEI 2-14 IEC 60034-7
    Code I Code II Code I Code II
    Frame Sizes
    56-200
    V6 IM 1031 Upon request IM V6
    This catalogue is only a reference for users.
    The concrete data be changed please contact with us before ordering.
    W2 U 2 V2
    U 1 V1 W1
    Y ?
    U
    W2 U2 V 2
    1 V1 W1
    PTC
    1
    2
    P
    P
    2
    3
    AC
    (L)
    E
    P
    F
    G
    D
    T
    M N
    4-S
    HD
    L
    AC
    TBW
    E
    R
    T
    N
    TBS F
    G
    D
    TBH
    P
    M
    S
    HD
    Overall & Installation Dimensions
    Frame Foot Mounting Shaft General
    H A B C D E F G K AA AD HD AC L TBS TBW TBH
    80 80 125 100 50 Ф19 40 6 15.5 Ф9 160 220 140 Ф158 280 16 97 97
    90S/L 90 140 100/125 56 Ф24 50 8 20 Ф10 175 240 150 Ф176 325/350 16 97 97
    100 100 160 140 63 Ф28 60 8 24 Ф12 200 265 165 Ф199 388 20 118 118
    112 112 190 140 70 Ф28 60 8 24 Ф12 230 291 179 Ф220 405 29 118 118
    132S/M 132 216 140/178 89 Ф38 80 10 33 Ф12 255 332 200 Ф259 467/505 29 118 118
    160M/L 160 254 210/254 108 Ф42 110 12 37 Ф15 314 402 242 Ф313 605/650 91 162 187
    180M/L 180 279 241/279 121 Ф48 110 14 42.5 Ф15 348 439 259 Ф360 687/725 160/180 162 187
    200L 200 318 305 133 Ф55 110 16 49 Ф19 388 497 297 Ф399 768 192 186 233
    225S 4,8 225 356 286 149 Ф60 140 18 53 Ф19 436 553 328 Ф465 814 190 186 233
    225M 2 225 356 311 149 Ф55 110 16 49 Ф19 436 553 328 Ф465 809 202 186 233
    4,6,8 225 356 311 149 Ф60 140 18 53 Ф19 436 553 328 Ф465 839 202 186 233
    250M 2 250 406 349 168 Ф60 140 18 53 Ф24 484 616 366 Ф506 918 233 218 260
    4,6,8 250 406 349 168 Ф65 140 18 58 Ф24 484 616 366 Ф506 918
    984/1035
    984/1035
    233 218 260
    280S/M 2 280 457 368/419 190 Ф65 140 18 58 Ф24 557 668 388 Ф559 265 218 260
    4,6,8 280 457 368/419 190 Ф75 140 20 67.5 Ф24 557 668 388 Ф559 265 218 260
    315S 2 315 508 406 216 Ф65 140 18 58 Ф28 630 840 525 Ф680 1160 130 350 430
    4,6,8 315 508 406 216 Ф80 170 22 71 Ф28 630 840 525 Ф680 1190 130 350 430
    315M/L 2 315 508 457/508 216 Ф65 140 18 58 Ф28 630 840 525 Ф680 1310 130 350 430
    4,6,8 315 508 457/508 216 Ф80 170 22 71 Ф28 630 840 525 Ф680 1340 130 350 430
    355M/L 2 355 610 560/630 254 Ф75 140 20 67.5 Ф28 740 920 565 Ф820 1770 180 350 430
    4,6,8 355 610 560/630 254 Ф95 170 25 86 Ф28 740 920 565 Ф820 1840 180 350 430
    Bearings
    Cable Gland Oil Seal
    Drive End Non-Drive End Drive End Non-Drive End
    6204ZZ
    6205ZZ
    6206ZZ
    6306ZZ
    6308ZZ
    6309C3
    6311C3
    6312C3
    1-M20×1.5
    1-M20×1.5
    1-M20×1.5
    2-M25×1.5
    2-M25×1.5
    2-M32×1.5
    2-M32×1.5
    2-M40×1.5
    6313C3 2-M50×1.5
    6314C3 2-M50×1.5
    6316C3 2-M50×1.5
    2-M63×1.5
    2-M63×1.5 6319C3
    6317C3
    NU319
    NU322
    6319C3
    6322C3
    20x34x7
    25x37x7
    30x44x7
    30x44x7
    40x58x7
    45x65x8
    55x72x8
    60x80x8
    65x90x10
    65x90x10
    65x90x10
    70x95x10
    70x95x10
    80x100x10
    80x100x10
    85x110x12
    95x120x12
    95x120x12
    110x140x12
    20x34x7
    25x37x7(20x34x7)
    30x44x7
    30x44x7
    40x58x7
    45x65x8
    55x72x8
    60x80x8
    65x90x10
    65x90x10
    65x90x10
    70x95x10
    70x95x10
    80x100x10
    80x100x10
    85x110x12
    95x120x12
    95x120x12
    110x140x12
    IM B5 3 IM B14 4
    4
    Model Power
    (KW)
    Full Load Speed
    (r/min)
    Inl 400V
    (A)
    Ifl 400V
    (A)
    Ist /In
    (Times)
    Eff.
    100%FL
    (%)
    Power Factor
    (CosΦ)
    Full Load Torque
    (N.M)
    Tst /Tn
    (Times)
    Tmin/Tn
    (Times)
    Tmax /Tn
    (Times)
    2 Pole - 3000 rpm Synchronous Speed 50Hz
    T1A 801-2 0.75 2838 1.09 2.06 5 72.1 0.73 2.52 2.2 1.9 2.6
    T1A 802-2 1.1 2836 1.54 2.90 5 75 0.73 3.70 2.2 1.8 2.6
    T1A 90S-2 1.5 2842 1.98 3.79 5 77.2 0.74 5.04 2.2 1.8 2.5
    T1A 90L-2 2.2 2835 2.39 5.04 5.5 79.7 0.79 7.41 2.2 1.8 2.5
    T1A 100L-2 3 2841 2.97 6.56 5.5 81.5 0.81 10.08 2.3 1.9 2.6
    T1A 112M-2 4 2900 3.88 8.58 6 83.1 0.81 13.17 2.4 1.9 2.6
    T1A 132S1-2 5.5 2895 4.65 11.16 6 84.7 0.84 18.14 2.3 2 2.6
    T1A 132S2-2 7.5 2900 5.98 14.81 6.4 86 0.85 24.70 2.3 2 2.7
    T1C 160M1-2 11 2910 7.85 20.83 6.3 87.6 0.87 36.10 2.3 2 2.7
    T1C 160M2-2 15 2908 10.57 28.06 6.8 88.7 0.87 49.26 2.3 2 2.7
    T1C 160L-2 18.5 2912 11.69 33.60 7 89.3 0.89 60.67 2.3 2 2.7
    T1C 180M-2 22 2920 13.81 39.69 7.2 89.9 0.89 71.95 2.3 2 2.6
    T1C 200L1-2 30 2915 18.67 53.64 7 90.7 0.89 98.28 2.3 2 2.6
    T1C 200L2-2 37 2920 22.90 65.80 7.2 91.2 0.89 121.00 2.3 2 2.7
    T1C 225M-2 45 2920 26.21 78.70 7 91.7 0.90 147.16 2.3 2 2.7
    T1C 250M-2 55 2930 35.47 97.85 7.8 92.2 0.88 179.25 2.2 1.9 2.5
    T1C 280S-2 75 2930 45.66 131.22 7.8 92.7 0.89 244.44 2.1 1.9 2.5

     


    在線詢盤/留言 請(qǐng)仔細(xì)填寫準(zhǔn)確及時(shí)的聯(lián)系到你!
    您的姓名: * 預(yù)計(jì)需求數(shù)量: *    
    聯(lián)系手機(jī): * 移動(dòng)電話或傳真:
    電子郵件: * 所在單位:
    咨詢內(nèi)容:
    *
     
    更多..本企業(yè)其它產(chǎn)品

    機(jī)電之家網(wǎng) - 機(jī)電行業(yè)權(quán)威網(wǎng)絡(luò)宣傳媒體

    Copyright 2025 jdzj.com All Rights Reserved??技術(shù)支持:機(jī)電之家 服務(wù)熱線:0571-87774297

    網(wǎng)站經(jīng)營(yíng)許可證:浙B2-20080178-4